DC UPS 400W switching power supply 12V with battery charging For Communication equipment 
 
	Description: 
 
	 
	KAIHUI DC-UPS converters cover power ranges from 10-500W in single and dual outputs. Available on enclosed types,  and its range is constantly expanding to fulfill the growing demands of miniaturization and high power density applications. 
	
		
	
 
 
	Features: 
	 
	1,400w 12v power supply with small size and high power;
2,  400w DC UPS power supply with wide range of ac input voltage;
3,  Protection: short circuit, overload, overvoltage and etc. 
	 
	
		
			
				| Parameter 
 | 
			
				| Item NO | 
						KDC400-12 
					 | 
			
				| Output | 
						Output Voltage 
					 | CH1:+12VDC;      CH2:+13.8VDC | 
			
				| 
						Rated Current 
					 | CH1:25A;                 CH2:2A | 
			
				| 
						Current Range 
					 | CH1:0-25A;          CH2:0-2A | 
			
				| 
						Rated Power 
					 | 400W | 
			
				| 
						Ripple & Noise 
					 | CH1:150mVp-p;  CH2:200mVp-p | 
			
				| 
						Adjustable Output Range 
					 | 
						±10% 
					 | 
			
				| 
						Output Accuracy 
					 | 
						±5% 
					 | 
			
				| 
						Line Regulation 
					 | 
						CH1:±0.5%    CH2:+/-1% 
					 | 
			
				| 
						Load Regulation 
					 | 
						CH1:±0.5%     CH2: +/-4% 
					 | 
			
				| 
						Set up,Rise,Keep up time 
					 | 
						300ms, 50ms, 20ms 
					 | 
			
				| Input | 
						Input Voltage Range 
					 | 
						88-132V AC,176~264vac by switching 
					 | 
			
				| 
						Input Current 
					 | 
						6A/115V,3A/230V 
					 | 
			
				| 
						Input Frequency 
					 | 
						47~63Hz 
					 | 
			
				| 
						Efficiency 
					 | 
						>85%@230V 
					 | 
			
				| Power Factor | 
						60%@230VAC 
					 | 
			
				| 
						Inrush Current 
					 | Cool start 40A/230V | 
			
				| 
						Leakage Current 
					 | 
						<0.5mA@240V 
					 | 
			
				| Protection | 
						Over Load Protection 
					 | 
						105~150%,Hiccup protection,automatic recovery 
					 | 
			
				| 
						Short Circuit Protection 
					 | 
						Hiccup,automatic recovery 
					 | 
			
				| Output over-voltage protection | 
						>150% automatic recovery 
					 | 
			
				| 
						Over-temperature protection 
					 | 
						>105 ℃ protection, automatic recovery 
					 | 
			
				| 
						Environment 
					 
 | 
						Working Temp.,Humidity 
					 | 
						-20~50℃,10~90% RH,No condensation 
					 | 
			
				| 
						Storage Temp.,Humidity 
					 | 
						-20~85℃,10~95% RH 
					 | 
			
				| 
						Temp.,Drift 
					 | 
						±0.03%/℃(0~50℃) 
					 | 
			
				| 
						Vibration 
					 | 
						10~500Hz, 2G 10min /1cycle,PERIOD FOR 60min EACH AXES 
					 | 
			
				| 
						Safety&EMC Standards 
					 
 | 
						Safety Standards 
					 | 
						GB4943 
					 | 
			
				| 
						Withstand Voltage 
					 | 
						I/P-O/P:4KV;I/P-FG:1.5KV;O/P-FG:0.5KV AC 
					 | 
			
				| 
						Insulation Resistance 
					 | 
						I/P-O/P,I/P-FG,O/P-FG:500VDC / 100M Ohms 
					 | 
			
				| 
						EMC Standards 
					 | 
						......
					 | 
			
				| Others | Dimension | 
						215*115*50mm(L*W*H) 
					 | 
			
				| Weight | 0.9kg | 
			
				| MTBF | 
						>50hrs 
					 | 
			
				| Fan Supply | YES | 
			
				| Notes | 
						1. All parameters 230VAC input, rated load, ambient temperature 25 ℃, measured under conditions of 70% humidity; 
					 
						2. Accuracy: includes set up tolerance, line regulation, load regulation and so on; 
					 
						3. Ripple Test: 30cm long strands connect the power supply and the load on the load side and 0.1u and 47u capacitor to 20MHz oscilloscope measured at the load end; 
					 
						4. Line regulation: at rated load conditions, the input voltage changes from low to high measured; 
					 
						5. Load regulation: the measured output load from 0 to 100% load change measured. 
					 | 
		
	
 
	Product picture: 
	
 
	
	 
 
	 
 
	 
 
	 
 
	 
 
	