Copper Foil for Battery Anode Substrate 
	
	
	 
	
		
			
				| 
						NO 
					 | 
						Items 
					 | 
						Criteria 
					 | 
						Remarks 
					 | 
			
				| 
						1 
					 | 
						Vibration test 
					 | 
						The battery is to be tested in three mutually perpendicular to each axis. 
					 | 
						No fire, no explosion 
					 | 
			
				| 
						2 
					 | 
						Drop Test 
					 | 
						Drop the battery from 1m height onto 5cm it 3 times each of X, Y, and Z directions at 25±2°C 
					 | 
			
				| 
						3 
					 | 
						Short circuiting Test 
					 | 
						After standard charge,the battery shall be subjected to a short-circuit condition with a wire of resistance less than 100(o) 
					 | 
			
				| 
						4 
					 | 
						High temperature test 
					 | 
						Leaving the battery at 85°C for 4hours after standard charge 
					 | 
						No fire, no explosion 
					 
						Capacity≥80%C5 
					 | 
			
				| 
						5 
					 | 
						Heating Test 
					 | 
						The temperature of the oven is to be raised at a rate of 5±2°C/min to a temperature of 130±2°C for 30 minutes. 
					 | 
						No explosion, no fire 
					 | 
			
				| 
						6 
					 | 
						Overcharge testing 
					 
						(NO PCM) 
					 | 
						3C 4.6V. 
					 | 
			
				| 
						7 
					 | 
						Storage Characteristics 1 
					 | 
						standard charge and then storage at 25±2°C for 30 days. 
					 | 
						Remaining Capacity≥85% 
					 | 
			
				| 
						8 
					 | 
						Storage Characteristics 2 
					 | 
						1 
					 | 
						after standard charge and then storage at 60±2°C for 7 days. 
					 | 
						Remaining Capacity≥60% 
					 | 
			
				| 
						2 
					 | 
						the capacity on standard discharge shall be measured after standard charge. 
					 | 
						Recovery capacity≥80% 
					 | 
		
	
 
	
	
	 
 
	
	 
 
	 
 
	 
	
		
 
 
	
	
		 
 
	
	
		    
 
	
	
		 
 
	
	
		
 
 
	
	