About product :   
	
		
			| 
				 
					Brand
				 
			 | 
			
				 
					Honeywell
				 
			 | 
		
		
			| 
				 
					Part Number
				 
			 | 
			
				 
					10012/1/2
				 
			 | 
		
		
			| 
				 
					Product Type
				 
			 | 
			
				 
					Central Processing Unit
				 
			 | 
		
		
			| 
				 
					Payment
				 
			 | 
			
				 
					T/T,100% advance payment
				 
			 | 
		
		
			| 
				 
					Shipping Port
				 
			 | 
			
				 
					Xiamen,China
				 
			 | 
		
		
			| 
				 
					Lead Time
				 
			 | 
			
				 
					In stock
				 
			 | 
		
	
	
	The 10012/1/2 is a Central Processing Unit designed to ensure system reliability and safety by responding effectively to faults. Depending on the location of the fault, the system can initiate a shutdown of the affected channel's output signal, a group shutdown for the channel, or a complete system shutdown. Fault responses, such as "System shutdown," "Process group shutdown," or "Alarm," must be pre-programmed to handle these scenarios.
In cases of defective digital inputs, the system reads them as a "0 signal," while for analog inputs, it adopts the configured minimum limit. The unit supports an absolute maximum input signal of ±36 Vdc, has crosstalk immunity greater than 60 dB, and includes external voltage readback capabilities ranging from 0 to 4.1 V, with an input resistance typically around 1 MOhm. Additionally, output comparison errors are flagged, ensuring faults are promptly addressed to maintain system integrity.
	
	FAQ:
Q1: What is the primary function of the 10012/1/2 Central Processing Unit?
A: The 10012/1/2 CPU manages critical system operations and ensures fault detection and response. It is designed to handle output comparison errors, initiate fault responses, and maintain system reliability.
Q2: How does the system respond to detected faults?
A: Fault responses depend on the fault's location and are pre-programmed to include:
Shutdown of the output signal for the affected channel
Group shutdown of the affected channel
Full system shutdown or alarm notification
Q3: How does the unit handle defective digital and analog inputs?
A:Defective digital inputs are read as a "0 signal."
For defective analog inputs, the system adopts the configured minimum limit
	 
 sales7@amikon.cn     
 86-18965423501   
86-18965423501
   
AMKPLC 
	
	
Advantage Brands:
	1.TRICONEX(3008,3625,3805E.3721,3700A 4351B...)
	2. BENTLY NEVADA(3500/42M ,3500/22M,3500/95.3500/05...)
	3. HIMA(F3330,F3236 ,F6217,F7126,F8621A....)
	4. FOXBORO(FBM203,FBM204,FBM217,FMB231...)
	5. (1756,1785,1771,1746,1769..)
	6.ABB (DSQC .....)
	7.GE(IC693,IC697,IC695,IS200,DS200) 
	8. BACHMANN(CM202,DI232,MPC240,NT255,AIO288...)
	9. ICS (T8403,T8431...)
	10.Honeywell(3300,3500...)
	11.Schneider(QUANTUM,MODICON...)