Low voltage Advanced Static Var Generator ASVG

The Advanced Static Var Generator provides the same dynamic performance as the SVG with the added benefit of combining harmonic mitigation. Available in 50/100kVar wall mount and 30/50/75/100/150kVar cabinet mount modules, 400/480/690VAC three phase.



Advanced Static Var Generator

The Advanced Static Var Generator provides the same dynamic performance as the SVG with the added benefit of combining harmonic mitigation. Available in 50/100kVar wall mount and 30/50/100kVar cabinet mount modules, 400/480/690VAC three phase.

advance static var generator
ASVG svg apf
Advanced Static Var Generator MEC ASVG


Extend your Power Factor Correction Performance

The requirement for power factor correction is the number one power quality issue faced by the vast majority of industrial and commercial installations. The second biggest power quality issue is harmonic mitigation.

  1. Commercial installations will often have elevated 3rd harmonics owing to single phase non-linear loads such as computer switch mode power supplies, LED lighting, electronics lighting ballasts, inverter heat pumps.
  2. Add a computer data centre backed up by UPS containing a six pulse rectifier and 5th, 7th, 11th harmonics can be added into the mix.
  3. Variable Speed Drives controlling air handler units within building HVAC systems can further elevate the 5th, 7th, 11th harmonics
  4. Industrial installations will often have high levels of variable speed drive loading as automation systems improve efficiencies and productivity. It is no uncommon to see very high levels of current harmonics and voltage harmonic distortion resulting from six pulse VSDs drawing predominantly 5th, 7th 11th harmonics.

Wouldn’t it be great if you could address both power factor correction and harmonic mitigation in one cost effective unit. The Advanced Static Var Generator (ASVG) does just that.

Power Factor Correction And Harmonics Filtering in One Unit

  1. Reactive power compensation: Cos ϕ = 1.00
  2. Capacitive and Inductive compensation: -1 to +1
  3. All the features and benefits of the SVG
  4. Mitigation of 3rd, 5th, 7th, 11th harmonic orders
  5. Unit capacity can be shared 50/50 between power factor correction and harmonics correction
  6. Current imbalance correction can correct for load imbalance across all three phases

The 3rd, 5th, 7th, 11th harmonic orders are the most prevalent in the majority of installations. A correctly sized ASVG can not only correct your displacement power factor to unity but also reduce your harmonics to <5% THDi. Dealing with both results in a near unity true power factor.


Applications

ZDDQ ASVG are widely used for fluctuating loads such as motors, variable frequency drives, melting furnace from Steel Rolling mills,Chemical industry,Cement plant, Suger plant, Textile, Hospitals, Hotels, Building segment,Automobile industry,Oil and gas industry, public grid etc.










Product Tags mec electronics          multifunction controller          optimization and control          control optimization          mec mec          mec electronics philippines corporation          multifunction control module          bypassing multifunction controllers          NMFC01 Multifunction Controller         

INQUIRY

Contact us for all information about the product


click here to leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.