| Model | SMT-12060V-DP2-2C | SMT-24060V-DP2-2C | SMT-36060V-DP2-2C | SMT-48060-DP2-2C | 
			
				| Output | DC Voltage | 12V (12-13.5V adjust by NFC) | 24V (24-26V adjust by NFC) | 36V (36-38V adjust by NFC) | 48V (48-50V adjust by NFC) | 
			
				| Voltage Tolerance | ±0.2V | 
			
				| Rated current | 5A | 2.5A | 1.67A | 1.25A | 
			
				| Rated power | 60W | 
			
				| Load Regulation | ±1% | 
			
				| Input | Standby power consumption | ≤0.5W | ≤0.5W | ≤0.5W | ≤0.5W | 
			
				| Voltage Range | 100-277VAC | 
			
				| Frequency Range | 47 - 63Hz | 
			
				| Power Factor(Typ.)@ full load | PF≥0.98@120VAC  PF≥0.96@230VAC  PF≥0.95@277VAC (Full loading) | 
			
				| THD(Typ.)@ full load | ≤15%@120VAC ;  ≤10%@230VAC;  ≤15%@277VAC | 
			
				| Efficiency(Typ.)@ full load | 86.5%@120VAC;   88.5%@230VAC;   88.5%@277VAC; | 
			
				| AC Current(Max.) | 0.8A | 0.8A | 0.8A | 0.8A | 
			
				| Inrush Current (Typ.) | 16A, 204s@50%Ipeak (120VAC);   60.8A, 104us@50%Ipeak (230VAC);37.6A, 312us@50%Ipeak (277VAC) | 
			
				| Leakage current | <0.5mA | 
			
				| Protection | Short Circuit | Hiccup mode, recover automatically after fault condition is removed | 
			
				| Over Load | ≤120% ,hiccup mode, recover automatically after fault condition is removed | 
			
				| Over temperature | Ambient temp. over 55℃±10℃, output will be off; recovers automatically after temp. drops. | 
			
				| Environ-ment | Working TEMP. | -40~+60℃ (see below derating curve) | 
			
				| Working Humidity | 20 - 90%RH,non-condensing | 
			
				| Storage TEM.,Humidity | -40 - +80℃,10 - 95%RH | 
			
				| TEMP.coefficient | ±0.03%/℃(0 - 50℃) | 
			
				| Vibration | 10~500Hz, 2G 10min./1 cycle,period for 60min. each along X,Y,Z axes | 
			
				| Safety & EMC | Safety standards | EN61347-1   EN61347-2-13 (EU)   &  UL8750  (US) | 
			
				| Withstand voltage | I/P-O/P:3.75KVAC (EU);    I/P-O/P:1.88KVAC (US) | 
			
				| Isolation resistance | I/P-O/P I/P-FG O/P-FG:100MΩ/500VDC/25℃/70%RH | 
			
				| EMC Emission | EN55015   EN61000-3-2  EN61000-3-3 (EU)≥50% Load  &  FCC Part 15 B (US) | 
			
				| EMC Immunity | EN61000-4-2,3,4,5,6 ,11,  EN61547 | 
			
				| Others | Weight | 0.35Kg | 
			
				| Dimension | 192.5x62x24mm(L*W*H) | 
			
				| packing | 290*215*140mm (20PCS/CTN ) | 
			
				| Notes | 1. All parameters NOT specially mentioned are measured at 120VAC/230VAC input , rated load and 25℃of ambient temperature. | 
			
				| 2. Tolerance: includes set up tolerance, line regulation and load regulation . | 
			
				| 3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again. |