Company profile

The XCH Biomedical brand test chambers will meet the temperature, wetness and vacuum test necessities of the biomedical field. exploitation advanced technology and glorious accessories, our product are widely known by customers for his or her stable and qualified performance. Therefore far, our products and services are distributed in additional than thirty countries round the world, similar to the United States, the United Kingdom, etc., and thousands of cooperative companies.

All products

150L - 500L Stability Test Chamber For Medicine

The single door medicine drug stability environmental testing chamber, using advanced high-quality components and manufacturing technology, stable and reliable performance, suitable for GMP certified users. Creates a temperature, humidity, light environment for drug stability evaluation. Suitable for accelerated testing, long-term testing, wet test, climatic test and strong light irradiation test. Model: 150SD~500SD-2 Capacity: 150L~500L TEMP Range: 10~65℃ Fluctuation: <±0.5℃ Deviation:<±1.0℃ Humidity Range: 20~95% Fluctuation: <±3.0%RH Deviation:<±3.0%RH Environment temperature: +5 ~ 35℃

Double door medical stability environmental test chamber

The Double Door Medicine Drug Stability Environmental Testing Chamber, using imported high-quality components and manufacturing technology, with Medicine Stability Chamber stable and reliable performance, suitable GMP certified users Model: 800SD~3000SD-2 TEMP Range: 10~65℃ TEMP Fluctuation: <±0.5℃ TEMP Deviation: < ±1.0℃ Humidity Range: 20 ~ 95% Humidity Deviation:< ±3%RH Capacity: 800L~3000L Environment temperature: +5 ~ 35℃

Pharmaceutical stability test chambers

The medical stability testing chamber Medicine Stability Chamber, two boxes are independently controlled, climatic test, CSD series, A box has temperature, the three functions of humidity and light can be equipped with near-ultraviolet lamps to meet the requirements of the guidelines for the stability test of the 2020 edition of the Pharmacopoeia; Box B only controls and records. Model: 320SD~620SD/CSD Temperature Range: 10~65℃ Temperature Fluctuation: <±0.5℃ Temperature deviation: <±2.0℃ Humidity Range: 20~95%RH Humidity deviation: < ±3%RH Power: AC 220V±10% 50HZ Environment temperature: +5 ~ 35℃

Comprehensive Drug Stability Test Chamber

The Medicine Stability Chamber, adopts quality imported components and manufacturing process, with stable and reliable performance, independent control and climatic test of three boxes and temperature and humidity control of A, B and C boxes. Model: 430SD~830SD/CSD TEMP Range: 15~65℃ Fluctuation: <±0.5℃ TEMP Deviation: < ±1.0℃ Humidity Range: 20 ~ 95% Humidity Deviation:< ±3%RH Capacity: 430L~830L Environment temperature: +5 ~ 35℃

Walk-in Constant Temperature and Humidity Stability Chamber

The XCH-8000SD Series newly airway system designed achieves uniform of temperature and humidity form different parts inside the chamber. The inner wall and duct plate are made of stainless steel 304. Observation window of hollow tempered glass with electrothermal film. Temperature Range: 20~ 50℃ Temperature Fluctuation:≤ ±0.5℃ Temperature Deviation:≤ ±1.0℃ Humidity Range:40~80%RH(or 20~80%RH)); Humidity Deviation:≤ ±3.0%RH Test Points Optional:40℃ /75%RH、25℃ /60%RH、30℃ /65%RH (40℃ /25%RH、25℃ /40%RH、25℃ /60%RH) Low Temperature Laboratory: 2 ~ 8℃

Strong Medicine Photostability Test Chamber

XCH-150TPS medicine Photostability Test Chamber is equipped with visible light and near-ultraviolet lamp tube, Medicine Stability Chamber can independently control the type of light source, and can print and record visible light illumination and near-ultraviolet radiation in real time. Visible light and near-ultraviolet can be directly set, automatically adjusted and precisely controlled. Model: 150TPS TEMP Range: 15~50℃ Fluctuation: <±0.5℃ TEMP Deviation: < ±2.0℃(SAME LEVEL) Light Range: Visible light range: 100 ~ 8000LUX Total illumination should not be less than 1.2 x 10^6Lux·hr UV range: NUV range: 0.84 ~ 5w/m squared; The near-UV energy is no less than 200w•hr/㎡ UV wavelength: NUV wavelength: 320 ~ 400nm;

Comprehensive medicine stability test chamber 150L-500L

The single door low temperature test chamber, using advanced high-quality components and manufacturing technology, stable and reliable performance, suitable for GMP certified users. Creates a temperature, humidity, light environment for low temperature test chamberevaluation. Suitable for accelerated testing, long-term testing, wet test, and strong light irradiation test. Model: 150-500CSD-2 Capacity: 150L TEMP Range: 10~65℃ Fluctuation: <±0.5℃ Deviation:<±1.0℃ Humidity Range: 20~95% Fluctuation: <±3.0%RH Deviation:<±3.0%RH Environment temperature: +5 ~ 35℃

Photostability Test Chamber XCH-250TPS

XCH-250TPS medicine Photostability Test Chamber is equipped with visible light and near-ultraviolet lamp tube, Medicine Stability Chamber can independently control the type of light source, and can print and record visible light illumination and near-ultraviolet radiation in real time. Visible light and near-ultraviolet can be directly set, automatically adjusted and precisely controlled. Model: 250TPS TEMP Range: 15~50℃ Fluctuation: <±0.5℃ TEMP Deviation: < ±2.0℃(SAME LEVEL) Light Range: Visible light range: 100 ~ 8000LUX Total illumination should not be less than 1.2 x 10^6Lux·hr UV range: NUV range: 0.84 ~ 5w/m squared; The near-UV energy is no less than 200w•hr/㎡ UV wavelength: NUV wavelength: 320 ~ 400nm;

Photostability Test Chamber XCH-500TPS

XCH-500TPS medicine Photostability Test Chamber is equipped with visible light and near-ultraviolet lamp tube, Medicine Stability Chamber can independently control the type of light source, and can print and record visible light illumination and near-ultraviolet radiation in real time. Visible light and near-ultraviolet can be directly set, automatically adjusted and precisely controlled. Model: 500TPS TEMP Range: 15~50℃ Fluctuation: <±0.5℃ TEMP Deviation: < ±2.0℃(SAME LEVEL) Light Range: Visible light range: 100 ~ 8000LUX Total illumination should not be less than 1.2 x 10^6Lux·hr UV range: NUV range: 0.84 ~ 5w/m squared; The near-UV energy is no less than 200w•hr/㎡ UV wavelength: NUV wavelength: 320 ~ 400nm;

Photostability Test Chamber XCH-250LTPS

XCH-250LTPS medicine Photostability Test Chamber is equipped with visible light and near-ultraviolet lamp tube, Medicine Stability Chamber can independently control the type of light source, and can print and record visible light illumination and near-ultraviolet radiation in real time. Visible light and near-ultraviolet can be directly set, automatically adjusted and precisely controlled. Model: 250LTPS TEMP Range: 15~50℃ Fluctuation: <±0.5℃ TEMP Deviation: < ±2.0℃(SAME LEVEL) Light Range: Visible light range: 100 ~ 8000LUX Total illumination should not be less than 1.2 x 10^6Lux·hr UV range: NUV range: 0.84 ~ 5w/m squared; The near-UV energy is no less than 200w•hr/㎡ UV wavelength: NUV wavelength: 320 ~ 400nm;

Photostability Test Chamber XCH-500LTPS

XCH-500LTPS medicine Photostability Test Chamber is equipped with visible light and near-ultraviolet lamp tube, Medicine Stability Chamber can independently control the type of light source, and can print and record visible light illumination and near-ultraviolet radiation in real time. Visible light and near-ultraviolet can be directly set, automatically adjusted and precisely controlled. Model: 500LTPS TEMP Range: 15~50℃ Fluctuation: <±0.5℃ TEMP Deviation: < ±2.0℃(SAME LEVEL) Light Range: Visible light range: 100 ~ 8000LUX Total illumination should not be less than 1.2 x 10^6Lux·hr UV range: NUV range: 0.84 ~ 5w/m squared; The near-UV energy is no less than 200w•hr/㎡ UV wavelength: NUV wavelength: 320 ~ 400nm;

Walk-in Stability Test Chamber 15000SD

The XCH-15000SD Series newly airway system designed achieves uniform of temperature and humidity form different parts inside the chamber. The inner wall and duct plate are made of stainless steel 304. Observation window of hollow tempered glass with electrothermal film. Temperature Range: 20~ 50℃ Temperature Fluctuation:≤ ±0.5℃ Temperature Deviation:≤ ±1.0℃ Humidity Range:40~80%RH(or 20~80%RH)); Humidity Deviation:≤ ±3.0%RH Test Points Optional:40℃ /75%RH、25℃ /60%RH、30℃ /65%RH (40℃ /25%RH、25℃ /40%RH、25℃ /60%RH) Low Temperature Laboratory: 2 ~ 8℃

Walk-in Stability Test Chamber 20000SD

The XCH-20000SD Series newly airway system designed achieves uniform of temperature and humidity form different parts inside the chamber. The inner wall and duct plate are made of stainless steel 304. Observation window of hollow tempered glass with electrothermal film. Temperature Range: 20~ 50℃ Temperature Fluctuation:≤ ±0.5℃ Temperature Deviation:≤ ±1.0℃ Humidity Range:40~80%RH(or 20~80%RH)); Humidity Deviation:≤ ±3.0%RH Test Points Optional:40℃ /75%RH、25℃ /60%RH、30℃ /65%RH (40℃ /25%RH、25℃ /40%RH、25℃ /60%RH) Low Temperature Laboratory: 2 ~ 8℃

Walk-in Stability Test Chamber 40000SD

The XCH-40000SD Series newly airway system designed achieves uniform of temperature and humidity form different parts inside the chamber. The inner wall and duct plate are made of stainless steel 304. Observation window of hollow tempered glass with electrothermal film. Temperature Range: 20~ 50℃ Temperature Fluctuation:≤ ±0.5℃ Temperature Deviation:≤ ±1.0℃ Humidity Range:40~80%RH(or 20~80%RH)); Humidity Deviation:≤ ±3.0%RH Test Points Optional:40℃ /75%RH、25℃ /60%RH、30℃ /65%RH (40℃ /25%RH、25℃ /40%RH、25℃ /60%RH) Low Temperature Laboratory: 2 ~ 8℃